Select Page

in Monrovia Liberia sales price shop near me near me shop factory supplier Φ 125mm Double Oil Case Roots Blower with 15kw Motor manufacturer best Cost Custom Cheap wholesaler

  in Monrovia Liberia  sales   price   shop   near me   near me shop   factory   supplier Φ 125mm Double Oil Case Roots Blower with 15kw Motor manufacturer   best   Cost   Custom   Cheap   wholesaler

Our technicians and engineers have 23 several years of Experience in the Bearing Sector. focus in energy transmission goods, CATV items, mechanical seal, hydraulic and Pheumatic, and advertising items. Our products are utilized in numerous fields. We make all sorts of roots blower, centrifugal blower, Our Principal products are as under:

Kind Diameter Charge of circulation Force
ESR-MJ(Intense Kind) Phi50~ Phi300mm .5~140m sup3/min nine.8KPa~ninety eight.8Kpa
ESR(Ordinary Type) Phi50~ Phi350mm .5~140m sup3/min nine.8KPa~seventy eight.4Kpa
ESR-H(EPT-stress Variety) Phi50~ Phi350mm .7~160m sup3/min fifty eight.8KPa~98.8Kpa
ESR-V(Vacuum EPT) Phi50~ Phi350mm .five~160m sup3/min nine.8KPa~fifty three.3Kpa
EL Collection Phi200~ Phi600mm twenty.3~750m sup3/min 9.8KPa~58.8Kpa
Multistage Centrifugal Blower
or C-Series
Phi250~ Phi500mm fifty~500m sup3/min 9.8KPa~98Kpa
ERR-ERG Kind Phi250~ Phi500mm one hundred twenty~420m sup3/min 9.8KPa~ninety eight.8Kpa

The functioning basic principle of the three-blade roots blower: two 3-lobed rotors are organized in the cavity, and the
suction port and the discharge port are opened on equally sides of the cavity. By means of the motion of a pair of
synchronous EPTs, the two rotors rotate in reverse instructions and Relying on the mutual engagement of the two
rotors, the suction port and the discharge port are isolated, and the gasoline in the chamber is pushed to accomplish the
objective of blowing.

Characteristic of our roots blower:
one. Massive adjustment of the air quantity
2. Low Sound
three. EPT efficiency
four. Reduced power cosumption
5. EPTT time existence
six. Trustworthy operating, easy routine maintenance,tiny footprint

The parameters of our roots blower:

Sort Ratary Pace
(r/min)
Strain Increase
(Kpa)
Ability
(m/min)
Shaft EPTT
(Kw)
EPT Device MaXiHu (West EPT) Dis.mn
Excess weight(Kg)
EPTT
(Kw)
ESR-50 1100-2120 9.eight-fifty eight.eight .65-2.fifty eight .three-3.fifty four .seventy five-4 128-158
ESR-sixty five 1100-2130 nine.8-fifty eight.8 .94-three.66 .38-4.46 .seventy five-5.5 a hundred and fifty five-185
ESR-eighty 1140-1900 nine.eight-58.eight two.34-five.43 1.04-seven.forty two 2.2-eleven 155-277
ESR-100 1060-1980 9.8-58.eight four.fifty seven-nine.05 1.35-twelve.15 three-fifteen 309-377
ESR-one hundred twenty five 980-1850 9.8-58.eight five.35-twelve.four 1.sixty five-5.19 5.5-18.5 408-451
ESR-125C 970-1830 nine.eight-58.eight seven.five-seventeen.57 3.2-eighteen.five 4-22 408-451
ESR-a hundred and fifty 810-1730 nine.8-fifty eight.8 ten.37-27.fifteen 3.eighty four-forty.eighty two 7.five-forty five 688-848
ESR-175 970-1520 nine.8-58.8 19.sixty five-36.65 7.2-45.ninety five 11-55 980-1080
ESR-200B 740-1450 9.eight-58.8 19.sixty five-forty four.eight 10.fifteen-sixty.forty four fifteen-seventy five 1272-1546
ESR-200 810-1480 nine.8-58.8 27.65-fifty nine.two 8.05-eighty,twelve fifteen-90 1272-1546
ESR-250B 1100-1480 nine.eight-fifty eight.eight 54.seventy seven-seventy seven.55 19.ninety seven-90.97 30-110 1490-2454
ESR-250 990-1480 9.eight-58.8 sixty one.four-ninety seven.fifty two 20.1-117.3 thirty-132 1490-2454
ESR-300 990-1480 9.8-58.eight 87.1-138.1 26.four-167.eight 37-185 3326-3446
ESR-350 730-1480 nine.8-fifty eight.eight seventy eight.41-177.31 55-250
ESR-50H 1230-2120 sixty three.7-98 .forty five-2.02 two.05-six.twelve three-seven.5 160–one hundred seventy
ESR-65H 1240-2130 sixty three.7-ninety eight .seventy eight-2.53 two.89-7.fifty five 4-11 198-230
ESR-80H 1140-1900 sixty three.7-ninety eight one.82-four.55 four.09-10.1 five.5-15 316-326
ESR-100H 1060-1980 63.seven-98 2.sixty five-eight.06 six.36-17.2 7.five-22 398-459
ESR-125H 980-1850 63.7-98 4.64-eleven.23 eight.ninety two-24.two 11-thirty 544-630
ESR-150H 810-1730 63.7-ninety eight nine.53-25.76 17.sixteen-65 eighteen.five-75 752-1571
ESR-200H 810-1480 sixty three.7-98 25.34-56.92 forty two.34-a hundred and twenty 55-132 1426-1934
ESR-250H 990-1480 sixty three.7-98 fifty eight-ninety three.seven eighty three.2-205 90-220 2980-3468
ESR300H 990-1480 sixty three.7-ninety eight 86.9-134.one 114.seven-270 132-280 3476-3998
ERF-245 650-980 9.eight-98 forty seven.five-97.four sixteen-183 eighteen.5-200 3630-3690
ERF-250 650-980 9.8-98 sixty one.six-120.4 19-227 22-250 4450-4500
ERF-290 650-980 nine.8-seventy eight.four ninety two.three-128 22-213 thirty-250 4890-4710
ERF-295 650-980 nine.eight-78.4 ninety seven.three-152.5 23-227 thirty-250 4890-4880
ERF-297 650-980 9.8-seventy eight.four 87.5-167.6 26-249 30-280 5330-5520
ERF-three hundred 650-980 9.eight-78.four a hundred and one.5-188.seven 29-278 37-315 5330-5520
ERF-350 650-980 9.8-seventy eight.4 126-224.9 34-249 45-280 5210-6470
ERG-300 590-730 9.8-ninety eight 128.three-196 38-362 45-400 9440-15710
ERG-350 590-730 9.eight-98 159.three-231.six forty three-420 55-450 9700-1571
ERG-four hundred 590-730 9.8-83.3 203.1-290.9 52-449 75-five hundred 10090-11390
ERG-445 590-730 9.8-seventy three.5 229.seven-327.8 fifty eight-477 seventy five-560 10600-12230
ERG-450 590-730 9.eight-73.5 262.4-366.two 64-496 seventy five-560 10600-12230
ERG-500 590-730 9.8-63.seven 327.4-452.4 seventy eight-529 90-560 12790-14620
ERF-240-V 650-980 -nine.eight- -49 38.1-78 13-seventy six 18.five-90 3420-3285
ERF-245-V 650-980 -nine.eight- -49 forty seven.5-97.4 sixteen-95 22-110 3425-3360
ERF-250-V 650-980 -9.8- -49 sixty three-a hundred and twenty 19-117 22-132 3910-3830
ERF-290-V 650-980 -9.eight- -forty nine 72.six-one hundred forty four 22-136 thirty-a hundred and sixty 4415-4270
ERF-295-V 650-980 -9.8- -49 seventy six.6-152 23-a hundred forty five 30-one hundred sixty 4425-4485
ERF-297-V 650-980 -nine.8- -forty nine 84.3-166.8 26-a hundred and sixty 30-a hundred and eighty 5000-4980
ERF-three hundred-V 650-980 -nine.8- -forty nine 97-192 29-178 37-two hundred 5000-4980
ERF-350-V 650-980 -9.eight- -49 116-225 34-209 forty five-250 5400-5700
ERG-300V 590-730 -9.eight- -forty nine 133-193 38-184 forty five-220 7800-9100
ERG-350V 590-730 -nine.eight- -forty nine 163-231 43-216 fifty five-250 9500-9470
ERG-400V 590-730 -9.eight- -49 199-290 52-269 seventy five-315 9900-10130
ERG-445V 590-730 -nine.eight- -forty nine 224.8-326.nine fifty eight-303 seventy five-355 9900-10130
ERG-450V 590-730 -9.eight- -49 255-365 64-335 seventy five-400 11230-11300
ERG-500V 590-730 -9.eight- -49 314-452 78-412 132-450 13630-13850
ERF-245W 650-980 -13.three- -53.three 53.5-a hundred and one 21.five-102 thirty-a hundred and ten 3630-3360
ERF-250W 650-980 -thirteen.three- -53.three 69-127 26.5-127 thirty-a hundred and sixty 3985-4115
ERF-290W 650-980 -13.3- -fifty three.three eighty two.6-150 thirty.5-149 37-185 4340-4580
ERF-295W 650-980 -13.3- -53.three 87-158 32-158 37-185 4440-4580
ERF-297W 650-980 -thirteen.three- -53.three ninety five-174 36-174 forty five-two hundred 5230-5130
ERF-300W 650-980 -13.three- -53.3 109-195 forty-193 fifty five-220 5230-5130
ERF-350W 650-980 -thirteen.three- -53.3 129-230 fifty-230 75-250 5840-5670
ERG-300W 590-730 -thirteen.three- -53.3 142-197 52-201 75-220 9100-9000
ERF-350W 590-730 -13.3- -53.3 168-234.four fifty nine-235.5 75-280 9500-9600
ERG-400W 590-730 -13.3- -53.3 220-276.six 71-292 ninety-315 9900-10130
ERG-445W 590-730 -thirteen.three- -53.3 244-294.six eighty two-331 ninety-400 11230-11300
ERG450W 590-730 -13.3- -53.3 275-368.5 91-366 a hundred and ten-400 11230-11300
ETRF-250
(240,250)
650-980 98-196 sixty four.eight-112 a hundred thirty five-355 a hundred and sixty-four hundred 8700-8600
ETRF-295
(245,295)
650-980 ninety eight-196 80.8-139 167-439 185-five hundred 9200-9100
ETRF-three hundred
(245,295)
650-980 98-176.4 102-174 206-497 250-560 10320-10500
ETRF-350
(245,295)
650-980 98-137.2 124-207 241-473 280-560 10700-11110
ETRG-four hundred
(three hundred,400)
590-740 ninety eight-176.4 205-273 380-773 450-900 21350-24200
ETRG-450
(350,450)
590-740 ninety eight-176.four 263-428 476-955 560-a thousand 24200-27600
ETRF-250W
(240,250)
650-980 -53.three–eighty seventy two-121 seventy five.six-121 ninety-160 6100-6470
ETRF-295W
(245/295)
650-980 -53.three–80 93.8-154 ninety nine.5-186 110-220 7000-6400
ETRF-300W
(2505/300)
650-980 -53.three–80 116-189 115-220 132-250 7750-7760
EL81WD 580-980 nine.8-fifty eight.8 fifty four.two-a hundred thirty eighteen-151 45-185 3595
EL82WDB 580-980 9.8-58.8 72.8-161 22-191 45-220 3860
EL83WDA 580-980 9.eight-fifty eight.nine one zero one-213 28.five-202 forty five-220 4300
EL84WDA 580-980 nine.eight-58.eight 129-267 35.four-252 45-280 4720
EL93WDA 580-730 9.8-49 230-329 fifty six.four-311 75-355 7765
EL94WDA 580-730 nine.eight-forty nine 263-373 sixty four-353 75-four hundred 8130
EL95WDA 490-580 nine.8-fifty eight.8 308-434 eighty one.four-414 90-450 11500
EL96WDA 580 fifty eight.eight 381 497 560 11500
E397WN one thousand-1650 forty 5-9
E408WN 870-1650 forty 10-22
E517WN 980-1580 forty twenty-30
E520WN 930-1550 forty 24-45
E607WN 750-1250 40 45-seventy six
E610WN 750-1250 forty 75-a hundred thirty

EPT parts and framework of our roots blower:

Package of our Roots Blower

Pack into iron circumstance, two layer,blower body and motor in lower layer, inlet/out silencer and so on in higher layer

Roots blower pack strategy exact same as iron situation, just change to Fumigation Free Plywood Situation

Our manufacturing facility is a skilled maker of Roots blowers which has above 20 years’ expertise in EPTTry
manufacturing. It is situated in XiHu (West EPT) Dis.hu (West EPT) Dis. EPT EPTT Park, 50 kilometers to the EPT of ZheJCEP provincial
funds— EPTEPTTn. Our organization also has hassle-free traffic transportation, as it is 15 kilometers away from
Diaozhen City station of EPTTngdao-HangEPT expressway, and 30 kilometers absent from EPT EPTEPTTn station of
BeiEPTTg-ZheJCEP expressway.The foremost product of our firm is ESR -sort Roots Blower. The roots
EPT pump is a new sort of large-efficiency roots blower, which is deveXiHu (West EPT) Dis.Hu (West EPT) Dis.ed independently based mostly on the
domestic and foreign EPTd systems. Many patEPTTd systems have been adopted on Roots
Blower, and therefore we have created considerable effects in strength conservation and sound reduction, and many others.. So significantly, our
organization has invested far more than 30,000,000 RMB to introduce this kind of EPTd expert products as
horizontal machining cEPTTr, vertical machining cEPTTr, two-way CNC floor planer, CNC lathe, CNC milling
EPTT, CNC planer, aircraft grinder, cylindrical grinding EPTT, and a few coordinates tests EPTT.
Apart from, we have taken numerous measures to stXiHu (West EPT) Dis.Hu (West EPT) Dis.rdize the process flow these kinds of as doing work and cooperating
with numerous EPT research units, faculties and universities at residence and abroad. We also repeatedly consider to
take up and increase the domestic EPTd manufacturing systems, so as to promote the upgrading and
optimization of the merchandise and make the solution high quality get to the EPTd stage at house and overseas.
ESR -variety Roots Blower incEPTTs numerous series such as Three-leaves Kind, Two-leaves Type and Centrifugal
Kind,which can be even more divided to hundreds of types. The merchandise are widely used in sewage treatment method,
pneumatic conveying,EPT EPTT, aquaculture, foods processing, electric EPTT, petrochemical, cement,
mining and other EPTT. Our goods have such rewards as minimal noise, energy preserving, secure quality,
and EPTT services lifestyle, etc.. With the revenue stores all through the domestic cash cities, our products market nicely all
above the nation, and have been exported to North The us,Russia, Malaysia, Indonesia, Vietnam, South Africa
and some other international locations. Possessing got the ISO9001 JCEP EPTT Technique Certification, we have
estabEPTTd and improved the good quality assurance of the items developing, production, and installation.
From the process of style, study and deveXiHu (West EPT) Dis.Hu (West EPT) Dis.ment to the finished items, we have obtained the EPTT
procedure controlled independently, thus supplying the entire basis and trustworthiness assure for the items security
and longevity. Obtaining a best revenue network and right after-product sales service, we supply our customers with larger-
good quality and more successful provider.All employees of our organization sincerely welcome the broad masses of close friends to
XiHu (West EPT) Dis.Hu (West EPT) Dis., and negotiate business with us.

Our Roots Blower Workshop

Doosn Horzitonal EPTT CEPTTr

The Application of the Roots Blower

Upkeep and inspection
(1) Check out all fasteners and finding pins problems whether they are loosening.
(two) AlwaEPTTcheck no matter whether the leakage phenomenon of the entire body.
(3) Shell out focus to lubrication, amount of grease and noises when operating,
deterEPT whether or not it performs unEPTTthe JCEP problems.
(four) Lubricant amp grease: The lubricant is for medium load EPTT EPT oil
(grade 220, kinematic viscosity of 198 ~ 242mm2 / s 40 ordmC, flash level ge two hundred ordmC)
The grease is butter (synthetic lithium grease penetration 220-250, fall point ge
one hundred ninety ordmC). Exchange the lubricant and grease right after first two hundred several hours running, and replace
once more soon after a moth working. Later on, replace the lubricant and grease according to the
atmosphere and lubricant (grease) top quality propose a appropriate replacement for 3
months.
(five) AlwaEPTTcheck the inlet air filter, clean or change the filter in time.
(6) Blower overload sometimes not immediately displayed, so pay out attention to
the ingestion and exhaust strain, bearing temperature and the existing increase developments
of motor to deterEPT no matter whether the blower performs normally
(7) Just before disassembling the blower, the assembling relation and proportions
must be recorded or calculated, make marks on elements to ensure the authentic
requirements right after assembling.
(8) When newly EPTT or overhaul, the oil tank should be cleaned before use
and propose change all grease right after 8 hours operating.

Frequent failure purpose and troubleshooting

No Failure Feasible factors Elimination strategies
one Friction
between the
impeller
(1) EPTTurities on the impeller,
resulting in the gap is way too modest
(2) EPT dress in, resulting in a
big backlash
(three) The EPT is not effectively set,
can not maintain the impeller
synchronization
(4) EPTT use resulting in
clearance rising.
(1) Take away dirt and verify
whether there is hurt parts
(two) Alter the EPT hole, substitute
the EPTs if the EPT backlash is
greater than the regular thirty% to
50%
(3)Re-assemble the EPTs, keep
the EPTTr get in touch with region is to seventy five%
(4)Exchange the bearing
two Collision
among
impeller and
wall, the
impeller leading
and casing
(one) Installation hole is not appropriate
(2) functioning strain is also
higher, exceeding the specified
value
(three) Operating temperature is way too high
(four) Casing or base deformation,
positioning fan failure
(5) EPTT aXiHu (West EPT) Dis.al spot is not good
(one) Adjust the hole
(two) Discover causes of
overloading, reduced the pressure
to the specified worth
(three) Examine the installation
precision and reduce the pipe
rigidity
(4) Verify and fix bearings,
and to guarantee the clearance
(five)Relocation
3 Temperature
also substantial
(one) Oil in tank is as well considerably, as well
thick or also dirty
(two) EPT or silencer is blocked
(3)The force is higher than
the specified value
(4)Extreme wear of the
impeller, big gap
(five)Poor air flow, indoor
temperature is large, ensuing in
inlet air’s substantial temperature
(six) The rotating speed is too reduced,consequence in the belt slipping.
(one)Decrease the oil stage or rely on
oil
(2)Eliminate of blocking objects
(three)Minimizing the pressure by way of
the blower
(4)Restore its clearance
(5)Open vents to minimize area
temperature
(6) Enhance pace to avert the
belt slipping.
four Inadequate
movement
(1) The inlet filter is blocked
(two) EPTTeller wear and the gap
raises as well a lot
(3) Belt slipping
(four) Big EPTTs strain decline
(five) EPTline ventilation leakage
(one) Clear the filter dust and
obstruction
(2) Repair the gap
(three)Tighten the belt and increase
the amount of belts
(four)Alter the inlet stress to the
specified price
(5) Examine and fix the pipeline
5 Oil leaking or
oil leaking
into the enclosure
(1)EPT tank situation trigger
leakage from the discharge port
(two) Seal dress in, resulting in shaft oil spills
(3) The stress is larger than
the specified price
(1)Decrease the oil stage
(2)Exchange the seals
(3)Obvious the air vents, 2mm diameter faucet is mounted in the
center chamber, open up the faucet
unEPTTthe wall
six Irregular
vibration and
sound
(one)EPTT clearance exceeds the
specified value or bearing wear
(two) The EPT backlash is also
big, not in a tigEPTT mounted
(three) The international objects and dust
caused by the impeller and the
impeller, the impeller and the
housing collision
(4) the impeller shaft
deformation caused the collision
induced by overload,
(five) Friction amongst the impeller
and the inlet housing triggered by
overheating
(six) Unbalance of the impeller
induced by fJCEP or foreign
human body
(seven) Anchor bolts or other
fasteners are loosened
(one)Exchange bearings or bearing
seat
(two)Reassemble EPT and make sure
backlash
(3)Cleaning blower, examine the
case is ruined
(4)Verify the again strain, verify
the wheel and alter gap
(5)Check the filter and back
force, improve the gap
among the impeller inlet and the
casing
(six)Clear the impeller and the
casing, to guarantee that the impeller
clearance perform
(7) Tighten the anchor bolts and
leveling the foundation.
7 EPT
overload
(1)When compared with the JCEP
pressure, the strain big difference
is large that the again pressure or
the inlet strain is substantial
(2) Compared with the
products needs, blower
stream is also big, so its force
will increase
(three)Inlet filter is blocked, or outlet
pipe is obstructed or blocked
(four) Collusion or friction (trapped)
rotating areas
(five) The oil stage is as well large
(six) NEPT V-belt is overheat,
vibration is as well massive, or pulley
is also modest
(1) Minimize the stress to the
specified price
(two) Exhaust the extra gas into
the environment or lessen the
blower speed
(3) Get rid of the obstructions
(four)Right away shut down, examine
the cause
(five) Adjust the oil to the proper
degree
(6) Examine the belt tension, and
changed it with big diameter
pulley.

Our Service

one. Pre promote support two. Right after sell services
a. recommend the suited design c. on the internet technical support,
b. factory tour d. EPTT lifestyle spare components and techinical assistance

Gurantee

twelve months gurantee for our roots blowers

  in Monrovia Liberia  sales   price   shop   near me   near me shop   factory   supplier Φ 125mm Double Oil Case Roots Blower with 15kw Motor manufacturer   best   Cost   Custom   Cheap   wholesaler

drive coupling

As one of leading drive coupling manufacturers, suppliers and exporters of products, We offer drive coupling and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of drive coupling

Recent Posts